Manufacturing · Vapi, Gujarat

Where your modules are made.

An automated module line in Vapi, run by people who treat every panel as a long-term commitment — whether it carries our name or yours.

OEM manufacturing

Every module, engineered for the long run.

OEM manufacturing means understanding your product, your quality expectations and the responsibility your brand carries. We agree the specification with you, build it consistently, and keep your commercial details confidential.

  • 01
    SpecificationTechnology, power class, bill of materials and construction agreed up front.
  • 02
    Sampling & approvalSamples and documentation reviewed before volume production.
  • 03
    Your brandNameplates, labels, packaging and datasheets prepared in your identity.
  • 04
    Production & qualityIn-line EL and flash testing on every module, batch after batch.
  • 05
    Dispatch & supportPacked, documented and supported after delivery.
A string of half-cells on the stringer
Cell technologyEverest MonoPERC · Zenith N-type TOPCon
Inside our facility

Precision, automated.

250 MWpOperational capacity
250 MWpAdditional capacity under installation
500 MWpTotal planned capacity
100+People across production, quality and engineering
The production line

From cell to module, every step is controlled.

Automation handles the repetition. Our people handle the judgement. Checks sit between the stages, not only at the end.

  1. Incoming inspectionCells, glass and encapsulant checked before they reach the line.
  2. Cell stringingHalf-cells soldered into strings on multi-busbar stringers.
  3. LayupRobotic placement of strings on glass and encapsulant.
  4. Bussing & pre-lamination ELStrings interconnected and imaged before the laminate is closed.
  5. LaminationHeat and vacuum bond the stack into one weather-tight laminate.
  6. Framing & junction boxAnodised frame, sealant and IP68 junction box fitted.
  7. Flash test & final ELEvery module power-classed and imaged again.
  8. Packing & dispatchLabelled, packed and documented under your brand.
Quality checks

Tested before it leaves Vapi.

Every module passes through the same sequence of checks, so a module in your warehouse behaves like the one you approved.

Electroluminescence imaging

EL imaging before and after lamination reveals micro-cracks and soldering faults invisible to the eye.

Flash testing

Each module is measured under a calibrated flash to confirm its power class before it is labelled.

Insulation & hi-pot

Electrical safety checks confirm insulation integrity ahead of packing.

Visual & dimensional

Glass, frame, sealant and junction box are inspected against the approved specification.

Quality & standards

Qualified to international standards.

Our modules are tested to the IEC and BIS standards that developers, EPC partners and financiers ask for, and every module is EL-inspected and flash-tested before it leaves Vapi.

ALMM listed · Everest MonoPERCBIS certified
Module design qualification and type approvalType-tested and certified
IEC 61215 / IS 14286
Module safety qualificationType-tested and certified
IEC 61730-1 & 2 / IS 61730-1 & 2
Salt mist corrosionType-tested and certified
IEC 61701
Ammonia corrosionType-tested and certified
IEC 62716
Potential-induced degradation (PID)Type-tested and certified
IEC 62804

See our modules in production.